HSD22-U

Overview:
HSD22-U data concentrator is a new generation of centralized meter reading terminal (DCU) developed and designed with reference to domestic and foreign advanced technical standards and combined with the actual needs of power users. The DCU uses 32-bit ARM9 and LINUX operating systems, with high-performance software and hardware platforms. The DCU uses a dedicated energy metering chip to ensure the accuracy and speed of data processing. The HSD22-U collector detects and analyzes the working conditions of the power grid and electric energy meters in real time, and actively reports abnormalities that can reduce the loss of power users to a minimum. The HSD22-U collector can be widely used in terminal meter reading, assessment and measurement, low-voltage centralized meter reading and other occasions.


Product Detail

Product Tags

Our personnel are always in the spirit of “continuous improvement and excellence”, and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer’s rely on for Leading Manufacturer for China Energy Meters Wireless Data Collector Terminal, We adhere towards the tenet of “Services of Standardization, to fulfill Customers’ Demands”.
Our personnel are always in the spirit of “continuous improvement and excellence”, and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer’s rely on for China Smart Meter Collector, Energy Meter Collector, We’ve more than 200 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 20 years own company grew stronger and stronger. We always apply the “client first” principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information remember to do no hesitate to contact us..

Highlight

MODULAR DESIGN

MODULAR DESIGN

MULTIPLE COMMUNICATION

MULTIPLE COMMUNICATION

LARGE STORAGE

LARGE STORAGE

SECURITY ENCRYPTION

SECURITY ENCRYPTION

HIGH PROTECTION DEGREE

HIGH PROTECTION DEGREE

Specifications

Item Parameter
Basic Parameter Active accuracy:Class 0.5S(IEC 62053-22)
Reactive accuracy:Class 2 (IEC 62053-23)
Rated voltage:3×230/400V
Operation voltage range:0.7 Un~1.3 Un
Frequency:50HzExtended operating frequency range:± 5%
Static power consumption≤10W
Operating temperature range:-40℃~+80℃
Storage temperature range:-40℃~+85℃
MCU & OS MCU series:ARM9
Data processing width:32bits
Kernel of operating system:Linux-2.6.19
SDRAM:64M
Communication Up-link:GPRS/3G/4G/Ethernet interfaceDLMS/COSEM on TCP/IP

DLMS/COSEM on HDLC

Down-link:RS485
PLC/G3-PLC/HPLC/RF/PLC+RF/Lora/Wi-Sun
DLMS/COSEM on TCP/IPDLMS/COSEM on HDLC
Local:Optical,LAN,RS485,RS232,USB
PLC Network Management Automatic establish PLC network topologyAutomatically discover the added meter at installation and as the result of the dynamic network topology changes.Self-configured

Self-healing

Meter Data Management Meter management:1200 pcs of PLC/RF 1P/3P meter,31 pcs of RS485 1P/3P meter
Task management:Auto configure task of reading meter,Auto configure data items of reading meter,

Interval cycle automatic collect meter data,

Resume broken collection for task management

Measurement Energy:kWh,kVarh,kVAh
Instantaneous:Voltage,Current,Active power,Reactive power,Apparent power, Phase angle, Power factor, Temperature
Load profile:Time,Status information,Power,Power factor
Average voltage and current profile record
EOB billing
Data Concentrator Management Self-checking:After power on,concentrator automatic check running environment and port status.
Self-monitor:Monitor running status of concentrator by watchdog,Inner monitor program detects status of Ethernet and user program.
RTC Clock accuracy:≤ 0.5s/day (in 23 ºC)
Support remotely time calibration with the systemSupport SNTP automatically network time calibrationExpected life at least 15 years
Storage Storage capacity of historic data:Nandflash:512MBPLC/RF Meter (1200 pcs)

Load profile (30 minutes interval):93 days/4800 records;

Billing Data (Monthly interval):12 months;

Event:each meter 600pcs recent records

CT Meter (31 pcs)

Load profile (half-hourly interval):93 days/4800 records;

Billing Data (Monthly interval):12 month;

Event:each meter 600pcs recent records

NVM,at least 15 years
Security DLMS suite 0/suite 1
Mechanical Enclosure protection:IP54
Support installation of seals
Concentrator case:Polycarbonate
Dimensions (L*W*H):290mm*180mm*95mm
Weight:Approx. 1.8kgs
Connection wiring Cross-sectional area:2.5-16mm²
Connection type:RRYYBBNN

Our personnel are always in the spirit of “continuous improvement and excellence”, and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer’s rely on for Leading Manufacturer for China Energy Meters Wireless Data Collector Terminal, We adhere towards the tenet of “Services of Standardization, to fulfill Customers’ Demands”.
Leading Manufacturer for China Smart Meter Collector, Energy Meter Collector, We’ve more than 1000 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 50 years own company grew stronger and stronger. We always apply the “client first” principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information remember to do no hesitate to contact us..