Highlight
MODULAR DESIGN
MULTIPLE COMMUNICATION
ANTI TAMPER
REMOTEUPGRADE
TIME OF USE
RELAY
HIGH PROTECTION DEGREE
Specifications
Type | Active accuracy | Reactive accuracy | Rated voltage | Specified operation range | Rated current | Starting current | Pulse constant |
DT meter | Class 1 (IEC 62053-21) | Class 2 (IEC 62053-23) | 3x110/190V | 0.8Un-1.2Un | 5(100)A 10(100) A 20(160)A | 0.004Ib | 1000imp/kWh 1000imp/kVarh (configurable) |
3x220/380V | 0.5Un-1.2Un | ||||||
3x230/400V | 0.5Un-1.2Un | ||||||
3x240/415V | 0.5Un-1.2Un | ||||||
CT meter | Class 0.5S (IEC 62053-22), | Class 2 (IEC 62053-23) | 3x110/190V | 0.8Un-1.2Un | 1(6)A 5(6)A 5(10)A | 0.001Ib | 10000imp/kWh 10000imp/kVarh (configurable) |
3x220/380V | 0.5Un-1.2Un | ||||||
3x230/400V | 0.5Un-1.2Un | ||||||
3x240/415V | 0.5Un-1.2Un | ||||||
CTVT meter | Class 0.2S (IEC 62053-22) | Class 2 (IEC 62053-23) | 3x57.7/100V | 0.7Un-1.2Un | 1(6)A 5(6)A 5(10)A | 0.001Ib | 10000imp/kWh 10000imp/kVarh (configurable) |
3x110/190V | 0.5Un-1.2Un | ||||||
3x220/380V | 0.5Un-1.2Un | ||||||
3x230/400V | 0.5Un-1.2Un | ||||||
3x240/415V | 0.5Un-1.2Un |
Item | Parameter |
Basic Parameter | Frequency:50/60Hz Current circuit power consumption≤0.3VA (Without module) Voltage circuit power consumption≤1.5W/3VA (Without module) Operating temperature range:-40°C ~ +80°C Storage temperature range:-40°C ~ +85°C |
Type Testing | DT Meter:IEC 62052-11 IEC 62053-21 IEC 62053-23 |
CT and CTVT Meter:IEC 62052-11 IEC 62053-22 IEC 62053-23 | |
Communication | Optical port RS485/P1/M-Bus/RS232 |
DT/CT Meter:GPRS/3G/4G/PLC/G3-PLC/HPLC/RF/ NB-IoT/Ethernet interface/Bluetooth etc. | |
CTVT:GPRS/3G/4G/NB-loT | |
IEC 62056/DLMS COSEM | |
Measurement | Three elements |
Energy:kWh,kVarh,kVAh | |
Instantaneous:Voltage,Current,Active power,Reactive Power,Apparent power, Power factor,Voltage and current angle,Frequency | |
Tariff Management | 8 tariff,10 daily time spans,12 day schedules,12 week schedules,12 seasons schedules,100 holidays (configurable) |
LED&LCD Display | LED indicator:Active pulse,Reactive pulse,Tamper alarm |
LCD Energy display:6+2/7+1/5+3/8+0,default 6+2 | |
LCD Display mode:Button display,Automatic display,Power-down display, Test mode display | |
Real Time Clock | Clock accuracy:≤0.5s/day (in 23°C) |
Daylight saving time:Configurable or automatic switching | |
Battery can be replaced Expected life at least 15 years | |
Event | Standard Event,Tamper Event,Power Event,etc. Event date and time At least 100 event records list (Customizable event list) |
Storage | NVM,at least 15 years |
Security | DLMS suite 0/suite 1/LLS |
Prepayment Function | Optional |
Mechanical | Installation:BS Standard/DIN Standard |
Enclosure protection:IP54 | |
Support installation of seals | |
Meter Case:Polycarbonate | |
Dimensions (L*W*H):290mm*170mm*85mm | |
Weight:Approx. 2.2kgs | |
Connection wiring Cross-sectional area:(10A) 2.5-16mm²;(100A) 4-50mm²;(160A) 4-70mm² | |
Connection type:(10A) AABBCCNN;(100A) AABBCCNN/ABCNNCBA; (160A) AABBCCNN |