Hot Product

Energy Meter

  • In Home Display (IHD)

    In Home Display (IHD)

    Highlight MULTIPLE COMMUNICATIONS LOW COST LOW POWER CONSUMPTION DATA TRANSMISSION Specifications Item Parameter Basic Power supply: P1: 5V, Type-C: 5V, Battery: 3V (2*AAA battery). Operating temperature range: -25°C ~ +70°C Communication (optional) Comm. 1: P1 115200bps DS...
  • DTSD546 Three Phase Four Wire Socket Type (16S/9S) Static TOU Meters

    DTSD546 Three Phase Four Wire Socket Type (16S/9S) Static TOU Meters

    SpecificationsItemSub-itemParameterBasicMeter Type3 Phase 4 WireMeter StandardANSIC12.1, ANSIC12.10, ANSI C12.20, ANSIC12.16, ANSI C62.41, ANSI C37.90.1, ANSI C12.18, ANSI C12.19, ASTM -B117, UL-50Active AccuracyActive Class 0.2, Reactive Class 1Rated voltage Un240VOperating Voltage Range0.7Un~1.15UnOperating frequency50HZ±5%Current16S: 30A(200A)/15(100A); 9S: 2.5A(20A)Starting current16S: 0.1A/0....
  • DIN Rail Single Phase Split Prepayment Energy Meter with Bottom Wiring

    DIN Rail Single Phase Split Prepayment Energy Meter with Bottom Wiring

    HighlightMODULAR DESIGN MULTIPLE COMMUNICATION ANTI TAMPER TIME OF USE REMOTEUPGRADE RELAY HIGH PROTECTION DEGREE SpecificationsItemParameterBasic ParameterActive accuracy:Class 1 (IEC 62053-21)Reactive accuracy:Class 2 (IEC 62053-23)Rated voltage:220/230/240VSpecified operation range:0.5Un~1.2UnRated current:5(60)/5(80)/10(80)/10(100)AStarting current:0.004IbFrequency:50/60HzPulse constant...
  • Single Phase Electricity Smart Meter

    Single Phase Electricity Smart Meter

    HighlightMODULAR DESIGN MULTIPLE COMMUNICATION ANTI TAMPER REMOTEUPGRADE TIME OF USE RELAY HIGH PROTECTION DEGREE SpecificationsItemParameterBasic ParameterActive accuracy:Class 1 (IEC 62053-21)Reactive accuracy:Class 2 (IEC 62053-23)Rated voltage:220/230/240VSpecified operation range:0.5Un~1.2UnRated current:5(60)/5(80)/10(80)/10(100)AStarting current:0.004IbFrequency:50/60HzPulse constant...
  • ANSI Standards Socket Base Electricity Meter

    ANSI Standards Socket Base Electricity Meter

    HighlightMODULAR DESIGN ANSI PROTOCOL WIDE VOLTAGE ANTI MAGNETIC RELAY TIME OF USE HIGH PROTECTION DEGREE SpecificationsFormVolts/Services Connection ClassAccuracyPulse constantFM1S120/240/120~480V,2-Wire,1-Element1P2W100/2000.5/0.2KH1.0FM2S120/240/120~480V,3-Wire,1/2-Element1P3W100/2000.5/0.2KH1.0FM4S120/240/120~480V,3-Wire,1.5-Element1P3W200.2KH0.2FM9S120/240/120~480V,4-Wire,3-Element3P4W...
  • Three Phase Smart Prepayment Card Meter

    Three Phase Smart Prepayment Card Meter

    HighlightMODULAR DESIGN MODULAR DESIGN MULTIPLE COMMUNICATION ANTI TAMPER REMOTEUPGRADE TIME OF USE RELAY HIGH PROTECTION DEGREE SpecificationsItemParameterBasic ParameterActive accuracy:Class 0.5S (IEC 62053-22)Reactive accuracy:Class 2 (IEC 62053-23)Rated voltage:3x220/380V,3x230/400V,3x240/415V,Specified operation range:0.5Un~1.2UnRated current:5(100)/10(100)A;Starting current:0.004IbFr...
  • Single Phase Static DIN Standard Electronic Meter

    Single Phase Static DIN Standard Electronic Meter

    HighlightMODULAR DESIGN SML PROTOCOL TIME OF USE HIGH PROTECTION DEGREE SpecificationsItemParameterBasic ParameterActive accuracy:Class A (EN50470-1-3) or Class 2 (IEC62053-21)Rated voltage:230VSpecified operation range:0.7Un~1.2UnRated current:5(60)AStarting current:0.004IbFrequency:50/60HzPulse constant:1000 imp/kWh (configurable) Current circuit power consumption≤4VAVoltage circuit power co...
  • Single Phase Multi-Functional Meter

    Single Phase Multi-Functional Meter

    HighlightMODULAR DESIGN ANTI TAMPER TIME OF USE RELAY HIGH PROTECTION DEGREE SpecificationsItemParameter Basic ParameterActive accuracy:Class 1 (IEC 62053-21)Rated voltage:220/230/240VSpecified operation range:0.7Un~1.2UnFrequency:50/60 HzRated current:5(100)/10(100)AStarting current:0.004IbPulse constant:1000 imp/kWh(configurable)Current circuit power consumption...
  • Three Phase Static DIN Standard Electronic Meter

    Three Phase Static DIN Standard Electronic Meter

    HighlightMODULAR DESIGN SML PROTOCOL MULTIPLE COMMUNICATION ANTI TAMPER TIME OF USE HIGH PROTECTION DEGREE SpecificationsItemParameterBasic ParameterActive accuracy:Class A (EN 50470-1-3) or Class 2 (IEC 62053-21)Rated voltage:3*230/400VSpecified operation range:0.7Un~1.2UnMeasuring current:5(60)/5(100)AStarting current:0.004IbFrequency:50/60HzPulse constant:500 or 5000 or 10000 imp/kWh(conf...
  • Three Phase Multi-functional Electricity Meter

    Three Phase Multi-functional Electricity Meter

    HighlightMODULAR DESIGN LOW COST MODULAR DESIGN HIGH PROTECTION DEGREE SpecificationsItemParameter Basic ParameterActive accuracy:Class 1 (IEC 62053-21)Rated voltage:3x230/400VSpecified operation range:0.7Un~1.2UnRated current:5 (100)/10(100)AStarting current:0.003IbFrequency:50/60HzPulse constant:1000 imp/kWh (configurable)Current circuit power consumption≤0.3VAVoltage circuit power consumpti...
  • Customer Interface Unit of Prepayment Meter

    Customer Interface Unit of Prepayment Meter

    Highlight3x4 KEYBOARD MULTIPLE COMMUNICATION SpecificationsItemParameterLED&LCD displayLED indicator:Remaining credit status,Communication,Event/Relay statusLCD display:Same with the MCU displayDisplay in scrolling mode and short code query with 8 digitsThe display contents are configurableBacklight is available for weak light condition.CommunicationPLC/G3-PLC/HPLC/RF/M-BusMechanicalEnclosure pr...
  • Three Phase Smart Prepayment Keypad Meter

    Three Phase Smart Prepayment Keypad Meter

    HighlightMODULAR DESIGN MODULAR DESIGN MULTIPLE COMMUNICATION ANTI TAMPER REMOTEUPGRADE TIME OF USE RELAY 3x4 KEYBOARD HIGH PROTECTION DEGREE SpecificationsTypeActive accuracyReactive accuracyRated voltageSpecified operation rangeRated currentStarting currentPulse constantDT meterClass 1(IEC 62053-21)Class 2(IEC 62053-23)3x110/190V0.8Un-1.2Un5(100)A10(100)A0.004Ib1000imp/kWh  1000imp/kVar...
21 Total
Leave Your Message
vr