products

OEM Famous Polymeric insulator Pricelist – Self-Supporting Aluminum Cable – Holley


Product Detail

Product Tags

Related Video

Feedback (2)

"Control the standard by the details, show the power by quality". Our organization has strived to establish a highly efficient and stable employees team and explored an effective high-quality command method for P1 Customer interface, RF UIU, China Electricity Meter Data Collector, Special emphasis around the packaging of merchandise to avoid any damage during transportation,Detailed interest into the useful feedback and strategies of our esteemed shoppers.
OEM Famous Polymeric insulator Pricelist – Self-Supporting Aluminum Cable – Holley Detail:

Specifications

DESCRIPTION

UNIT

VALUE

VALUE

VALUE

VALUE

VALUE

1

GENERAL

 

3×35 + 1×16 + NA25 mm2

3×50 + 1×16 + NA35mm2

3×70 + 1×16 + NA50 mm2 

3×25 + 1×16 + NA25 mm2 

3X120 + 1X16 + NA70 mm2

 

Manufacturing standard

 

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

2

DESIGNATION

CAAI

CAAI

CAAI

CAAI

CAAI

 

Rated Voltage Uo / U

kV

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

3

TERMS OF USE

 

Maximum temperature in permanent regime.

° C

90

90

90

90

90

 

Maximum temperature in overload regime. 

° C

130

130

130

130

130

 

Maximum temperature in short-circuit mode (5 s)

° C

 250

 250

 250

 250

 250

4

CABLES GATHERING:

 

Maximum wireways, depending on the diameter of thePhase wire

Times

60

60

60

60

60

5

PHASE CABLE:

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 

Material

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated Aluminum

 

Nominal section

mm2

35

50

70

25

120

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

12

6

15

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

0.868

0.641

0.443

1.20

0.253

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.52

1.52

1.14

2.03

Minimum thickness at one point

mm

1.03

1.37

1.37

1.03

1.83

6

STREET LIGHT CABLE

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

NTP 370.250

 

Material

 Pure Aluminum without Coating

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 

Nominal section

mm2

16

16

16

16

16

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

6

6

6

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

1.91

1.91

1.91

1.91

1.91

 

Insulation

 

Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

 

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

 

Minimum content of carbon black in XLPE

%

2

2

2

2

2

 

Minimum average thickness

mm

1.14

1.14

1.14

1.14

1.14

 

Minimum thickness at one point

mm

1.03

1.03

1.03

1.03

1.03

7

NEUTRAL CABLE SUPPORT
Standards

NTP 370.258

 NTP 370.258

 NTP 370.258

 NTP 370.258

NTP 370.258

Cable Material

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Conductivity

% IACS

52.5

52.5

52.5

52.5

52.5

Nominal section

mm2

25

35

50

25

70

Number of wires

7

7

7

7

7

Wire diameter

mm

2.13

2.52

3,023

2.13

3.57

 

Minimum tensile strength

kN

7.72

10.81

15.44

7.72

20.95

 

Nominal Mass

kg / km

68.4

95.7

136.8

68.4

191.5

 

Density at 20 ° C

kg / m3

2703

2703

2703

2703

2703

 

Electrical resistivity at 20 ° C

Ωmm2 / m

0.032840

0.032840

0.032840

0.032840

0.032840

 

Maximum electrical resistance in DC at 20 ° C

Ω / km

1.3511

0.9651

0.6755

1.3511

0.4825

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.14

1.52

1.14

1.52

Minimum thickness at one point

mm

1.03

1.03

1.37

1.03

1.37


Product detail pictures:

OEM Famous Polymeric insulator Pricelist –  Self-Supporting Aluminum Cable  – Holley detail pictures


Related Product Guide:

"Quality initially, Honesty as base, Sincere company and mutual profit" is our idea, in order to create repeatedly and pursue the excellence for OEM Famous Polymeric insulator Pricelist – Self-Supporting Aluminum Cable – Holley , The product will supply to all over the world, such as: Iraq, Estonia, USA, With top quality products, great after-sales service and warranty policy, we win trust from many overseas partner, many good feedbacks witnessed our factory's growth. With full confidence and strength, welcome customers to contact and visit us for future relationship.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Olga from Sri Lanka - 2018.12.10 19:03
    This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Ina from Ghana - 2018.09.12 17:18
    Write your message here and send it to us