It really is a good way to further improve our goods and service. Our mission would be to acquire inventive items to buyers with a very good encounter for 4G module, 3G meter, 3KA, As an expert specialized in this field, we are committed to solving any problem of high temperature protection for users.
OEM Famous Field data management Company – Self-Supporting Aluminum Cable – Holley Detail:

Specifications

DESCRIPTION

UNIT

VALUE

VALUE

VALUE

VALUE

VALUE

1

GENERAL

 

3×35 + 1×16 + NA25 mm2

3×50 + 1×16 + NA35mm2

3×70 + 1×16 + NA50 mm2 

3×25 + 1×16 + NA25 mm2 

3X120 + 1X16 + NA70 mm2

 

Manufacturing standard

 

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

2

DESIGNATION

CAAI

CAAI

CAAI

CAAI

CAAI

 

Rated Voltage Uo / U

kV

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

3

TERMS OF USE

 

Maximum temperature in permanent regime.

° C

90

90

90

90

90

 

Maximum temperature in overload regime. 

° C

130

130

130

130

130

 

Maximum temperature in short-circuit mode (5 s)

° C

 250

 250

 250

 250

 250

4

CABLES GATHERING:

 

Maximum wireways, depending on the diameter of thePhase wire

Times

60

60

60

60

60

5

PHASE CABLE:

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 

Material

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated Aluminum

 

Nominal section

mm2

35

50

70

25

120

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

12

6

15

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

0.868

0.641

0.443

1.20

0.253

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.52

1.52

1.14

2.03

Minimum thickness at one point

mm

1.03

1.37

1.37

1.03

1.83

6

STREET LIGHT CABLE

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

NTP 370.250

 

Material

 Pure Aluminum without Coating

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 

Nominal section

mm2

16

16

16

16

16

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

6

6

6

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

1.91

1.91

1.91

1.91

1.91

 

Insulation

 

Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

 

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

 

Minimum content of carbon black in XLPE

%

2

2

2

2

2

 

Minimum average thickness

mm

1.14

1.14

1.14

1.14

1.14

 

Minimum thickness at one point

mm

1.03

1.03

1.03

1.03

1.03

7

NEUTRAL CABLE SUPPORT
Standards

NTP 370.258

 NTP 370.258

 NTP 370.258

 NTP 370.258

NTP 370.258

Cable Material

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Conductivity

% IACS

52.5

52.5

52.5

52.5

52.5

Nominal section

mm2

25

35

50

25

70

Number of wires

7

7

7

7

7

Wire diameter

mm

2.13

2.52

3,023

2.13

3.57

 

Minimum tensile strength

kN

7.72

10.81

15.44

7.72

20.95

 

Nominal Mass

kg / km

68.4

95.7

136.8

68.4

191.5

 

Density at 20 ° C

kg / m3

2703

2703

2703

2703

2703

 

Electrical resistivity at 20 ° C

Ωmm2 / m

0.032840

0.032840

0.032840

0.032840

0.032840

 

Maximum electrical resistance in DC at 20 ° C

Ω / km

1.3511

0.9651

0.6755

1.3511

0.4825

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.14

1.52

1.14

1.52

Minimum thickness at one point

mm

1.03

1.03

1.37

1.03

1.37


Product detail pictures:

OEM Famous Field data management Company –  Self-Supporting Aluminum Cable  – Holley detail pictures


Related Product Guide:

While in the past few years, our organization absorbed and digested innovative technologies both equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted for the advancement of OEM Famous Field data management Company – Self-Supporting Aluminum Cable – Holley , The product will supply to all over the world, such as: Algeria, Japan, Borussia Dortmund, We only supply quality products and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom products etc that can according to customer's requirement.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Megan from New Zealand - 2017.01.11 17:15
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Christine from Denver - 2017.09.29 11:19
    Write your message here and send it to us