OEM Famous Data collector Factories – Self-Supporting Aluminum Cable – Holley Detail:
Specifications
DESCRIPTION |
UNIT |
VALUE |
VALUE |
VALUE |
VALUE |
VALUE |
|
1 |
GENERAL |
|
3×35 + 1×16 + NA25 mm2 |
3×50 + 1×16 + NA35mm2 |
3×70 + 1×16 + NA50 mm2 |
3×25 + 1×16 + NA25 mm2 |
3X120 + 1X16 + NA70 mm2 |
|
Manufacturing standard |
|
NTP 370.254 |
NTP 370.254 |
NTP 370.254 |
NTP 370.254 |
NTP 370.254 |
2 |
DESIGNATION |
CAAI |
CAAI |
CAAI |
CAAI |
CAAI |
|
|
Rated Voltage Uo / U |
kV |
0.6 / 1 |
0.6 / 1 |
0.6 / 1 |
0.6 / 1 |
0.6 / 1 |
3 |
TERMS OF USE | ||||||
|
Maximum temperature in permanent regime. |
° C |
90 |
90 |
90 |
90 |
90 |
|
Maximum temperature in overload regime. |
° C |
130 |
130 |
130 |
130 |
130 |
|
Maximum temperature in short-circuit mode (5 s) |
° C |
250 |
250 |
250 |
250 |
250 |
4 |
CABLES GATHERING: | ||||||
|
Maximum wireways, depending on the diameter of thePhase wire |
Times |
60 |
60 |
60 |
60 |
60 |
5 |
PHASE CABLE: | ||||||
|
Standard |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
|
|
Material |
Pure uncoated aluminum |
Pure uncoated aluminum |
Pure uncoated aluminum |
Pure uncoated aluminum |
Pure uncoated Aluminum |
|
|
Nominal section |
mm2 |
35 |
50 |
70 |
25 |
120 |
|
Class |
2 |
2 |
2 |
2 |
2 |
|
|
Minimum number of wires |
No. |
7 |
6 |
12 |
6 |
15 |
|
Maximum electrical resistance in DC at 20 ° C |
Ohm / km |
0.868 |
0.641 |
0.443 |
1.20 |
0.253 |
|
Insulation | ||||||
Material |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
||
XLPE requirement |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
||
Minimum content of carbon black in XLPE |
% |
2 |
2 |
2 |
2 |
2 |
|
Minimum average thickness |
mm |
1.14 |
1.52 |
1.52 |
1.14 |
2.03 |
|
Minimum thickness at one point |
mm |
1.03 |
1.37 |
1.37 |
1.03 |
1.83 |
|
6 |
STREET LIGHT CABLE | ||||||
|
Standard |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP 370.250 |
|
|
Material |
Pure Aluminum without Coating |
Pure uncoated aluminum |
Pure uncoated aluminum |
Pure uncoated aluminum |
Pure uncoated aluminum |
|
|
Nominal section |
mm2 |
16 |
16 |
16 |
16 |
16 |
|
Class |
2 |
2 |
2 |
2 |
2 |
|
|
Minimum number of wires |
No. |
7 |
6 |
6 |
6 |
6 |
|
Maximum electrical resistance in DC at 20 ° C |
Ohm / km |
1.91 |
1.91 |
1.91 |
1.91 |
1.91 |
|
Insulation | ||||||
|
Material |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
|
|
XLPE requirement |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
|
|
Minimum content of carbon black in XLPE |
% |
2 |
2 |
2 |
2 |
2 |
|
Minimum average thickness |
mm |
1.14 |
1.14 |
1.14 |
1.14 |
1.14 |
|
Minimum thickness at one point |
mm |
1.03 |
1.03 |
1.03 |
1.03 |
1.03 |
7 |
NEUTRAL CABLE SUPPORT | ||||||
Standards |
NTP 370.258 |
NTP 370.258 |
NTP 370.258 |
NTP 370.258 |
NTP 370.258 |
||
Cable Material |
Aluminium alloy |
Aluminium alloy |
Aluminium alloy |
Aluminium alloy |
Aluminium alloy |
||
Conductivity |
% IACS |
52.5 |
52.5 |
52.5 |
52.5 |
52.5 |
|
Nominal section |
mm2 |
25 |
35 |
50 |
25 |
70 |
|
Number of wires |
7 |
7 |
7 |
7 |
7 |
||
Wire diameter |
mm |
2.13 |
2.52 |
3,023 |
2.13 |
3.57 |
|
|
Minimum tensile strength |
kN |
7.72 |
10.81 |
15.44 |
7.72 |
20.95 |
|
Nominal Mass |
kg / km |
68.4 |
95.7 |
136.8 |
68.4 |
191.5 |
|
Density at 20 ° C |
kg / m3 |
2703 |
2703 |
2703 |
2703 |
2703 |
|
Electrical resistivity at 20 ° C |
Ωmm2 / m |
0.032840 |
0.032840 |
0.032840 |
0.032840 |
0.032840 |
|
Maximum electrical resistance in DC at 20 ° C |
Ω / km |
1.3511 |
0.9651 |
0.6755 |
1.3511 |
0.4825 |
|
Insulation | ||||||
Material |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
Cross-linked polyethylene XLPE |
||
XLPE requirement |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
According to table 2 of NTP 370.254 |
||
Minimum content of carbon black in XLPE |
% |
2 |
2 |
2 |
2 |
2 |
|
Minimum average thickness |
mm |
1.14 |
1.14 |
1.52 |
1.14 |
1.52 |
|
Minimum thickness at one point |
mm |
1.03 |
1.03 |
1.37 |
1.03 |
1.37 |
Product detail pictures:
Related Product Guide:
We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for OEM Famous Data collector Factories – Self-Supporting Aluminum Cable – Holley , The product will supply to all over the world, such as: Sri Lanka, United Kingdom, Angola, During the short years, we serve our clients honestly as Quality First, Integrity Prime, Delivery Timely, which has earned us an outstanding reputation and an impressive client care portfolio. Looking forward to working with you Now!
By Mary from Las Vegas - 2018.12.10 19:03
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
By Olive from Gabon - 2017.10.23 10:29