Specifications

DESCRIPTION

UNIT

VALUE

VALUE

VALUE

VALUE

VALUE

1

GENERAL

 

3×35 + 1×16 + NA25 mm2

3×50 + 1×16 + NA35mm2

3×70 + 1×16 + NA50 mm2 

3×25 + 1×16 + NA25 mm2 

3X120 + 1X16 + NA70 mm2

 

Manufacturing standard

 

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

2

DESIGNATION

CAAI

CAAI

CAAI

CAAI

CAAI

 

Rated Voltage Uo / U

kV

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

3

TERMS OF USE

 

Maximum temperature in permanent regime.

° C

90

90

90

90

90

 

Maximum temperature in overload regime. 

° C

130

130

130

130

130

 

Maximum temperature in short-circuit mode (5 s)

° C

 250

 250

 250

 250

 250

4

CABLES GATHERING:

 

Maximum wireways, depending on the diameter of thePhase wire

Times

60

60

60

60

60

5

PHASE CABLE:

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 

Material

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated Aluminum

 

Nominal section

mm2

35

50

70

25

120

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

12

6

15

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

0.868

0.641

0.443

1.20

0.253

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.52

1.52

1.14

2.03

Minimum thickness at one point

mm

1.03

1.37

1.37

1.03

1.83

6

STREET LIGHT CABLE

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

NTP 370.250

 

Material

 Pure Aluminum without Coating

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 

Nominal section

mm2

16

16

16

16

16

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

6

6

6

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

1.91

1.91

1.91

1.91

1.91

 

Insulation

 

Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

 

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

 

Minimum content of carbon black in XLPE

%

2

2

2

2

2

 

Minimum average thickness

mm

1.14

1.14

1.14

1.14

1.14

 

Minimum thickness at one point

mm

1.03

1.03

1.03

1.03

1.03

7

NEUTRAL CABLE SUPPORT
Standards

NTP 370.258

 NTP 370.258

 NTP 370.258

 NTP 370.258

NTP 370.258

Cable Material

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Conductivity

% IACS

52.5

52.5

52.5

52.5

52.5

Nominal section

mm2

25

35

50

25

70

Number of wires

7

7

7

7

7

Wire diameter

mm

2.13

2.52

3,023

2.13

3.57

 

Minimum tensile strength

kN

7.72

10.81

15.44

7.72

20.95

 

Nominal Mass

kg / km

68.4

95.7

136.8

68.4

191.5

 

Density at 20 ° C

kg / m3

2703

2703

2703

2703

2703

 

Electrical resistivity at 20 ° C

Ωmm2 / m

0.032840

0.032840

0.032840

0.032840

0.032840

 

Maximum electrical resistance in DC at 20 ° C

Ω / km

1.3511

0.9651

0.6755

1.3511

0.4825

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.14

1.52

1.14

1.52

Minimum thickness at one point

mm

1.03

1.03

1.37

1.03

1.37


Product detail pictures:

OEM Famous PT Pricelist –  Self-Supporting Aluminum Cable  – Holley detail pictures


Related Product Guide:

We have been convinced that with joint attempts, the business enterprise between us will bring us mutual benefits. We could guarantee you product or service good quality and aggressive value for OEM Famous PT Pricelist – Self-Supporting Aluminum Cable – Holley , The product will supply to all over the world, such as: Istanbul, Slovenia, Ottawa, Customer's satisfaction is always our quest, creating value for customers is always our duty, a long term mutual-beneficial business relationship is what we are doing for. We are an absolutely reliable partner for you in China. Of course, other services, like consulting, can be offered too.
  • This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Doreen from Spain - 2017.08.28 16:02
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Maria from Japan - 2018.02.12 14:52
    Write your message here and send it to us