DESCRIPTION | UNIT | VALUE | VALUE | VALUE | VALUE | VALUE | VALUE | VALUE | |
1 | GENERAL |
| 1X70mm2 8.7 / 15 (17.5) kV | 1x120mm2, 8.7 / 15 (17.5) kV | 1×150 mm2, 8.7 / 15 (17.5) kV | 1x70mm2, 18/30 (36) kV | 1X120mm2 FOR 18/30 (36) kV | 1×185 mm2, 8.7 / 15 (17.5) kV | 1X185mm2 FOR 18/30 (36) kV |
| Standard |
| NTP IEC 60502-2 | NTP IEC 60502-2 | NTP IEC 60502-2 | NTP IEC 60502-2 | NTP IEC 60502-2 | NTP IEC 60502-2 | NTP IEC 60502-2 |
2 | DESIGNATION N2XSY | 1 x 70 mm2 | 1 x 120 mm2 | 1 x 150 mm2 | 1 x 70 mm2 | 1 x 120 mm2 | 1 x 185 mm2 | 1 x 185 mm2 | |
| Rated Voltage Uo / U (Uo) | kV | 8.7 / 15 (17.5) | 8.7 / 15 (17.5) | 8.7 / 15 (17.5) | 18/30 (36) | 18/30 (36) | 8.7 / 15 (17.5) | 18/30 (36) |
| Maximum temperature under normal conditions | ° C | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
| Maximum short-circuit temperature (5 s. Maximum) | ° C | 250 | 250 | 250 | 250 | 250 | 250 | 250 |
3 | PHASE CONDUCTOR | ||||||||
| Standard | NTP IEC 60228 | NTP IEC 60228 | NTP IEC 60228 | NTP IEC 60228 | NTP IEC 60228 | NTP IEC 60228 | NTP IEC 60228 | |
| Material | Uncoated Annealed Copper | Uncoated Annealed Copper | Uncoated Annealed Copper | Uncoated Annealed Copper | Uncoated Annealed Copper | Uncoated Annealed Copper | Uncoated Annealed Copper | |
| Purity | % | 99.9 | 99.9 | 99.9 | 99.9 | 99.9 | 99.9 | 99.9 |
| Nominal section | mm2 | 70 | 120 | 150 | 70 | 120 | 185 | 185 |
| Class | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
| Minimum number of wires | No. | 19 | 37 | 37 | 19 | 37 | 37 | 37 |
| Density at 20 ° C | gr / cm3 | 8.89 | 8.89 | 8.89 | 8.89 | 8.89 | 8.89 | 8.89 |
| Electrical resistivity at 20 ° C | Wmm2 / m | 0.017241 | 0.017241 | 0.017241 | 0.017241 | 0.017241 | 0.017241 | 0.017241 |
| Maximum electrical resistance in DC at 20 ° C | Ohm / km | 0.268 | 0.153 | 0.124 | 0.268 | 0.153 | 0.099 | 0.099 |
| Insulation | ||||||||
Material | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | XLPE-TR (Tree Retardant Cross-linked Polyethylene) | ||
Colour | natural | natural | natural | natural | natural | natural | natural | ||
Average nominal thickness | mm | 4.5 | 4.5 | 4.5 | 8 | 8 | 4.5 | 8 | |
| Screen |
|
|
|
|
|
|
|
|
Semiconductor tape or extruded compound semiconductor on the conductor | YES | YES | YES | YES | YES | YES | YES | ||
About the insulator | |||||||||
Semiconductor tape or extruded composite semiconductor | YES | YES | YES | YES | YES | YES | YES | ||
| Copper wire braided mesh or tape with resistance less than 3 ohm/km at 20 ° C |
| YES | YES | YES | YES | YES | YES | YES |
Sheath | |||||||||
Material | PVC –ST2 | PVC – ST2 | PVC – ST2 | PVC –ST2 | PVC – ST2 | PVC – ST2 | PVC – ST2 | ||
Colour | Red | Red | Red | Red | Red | Red | Red | ||
Minimal thickness | mm | 1.2 | 1.2 | 1.3 | 1.4 | 1.5 | 1.4 | 1.6 | |
| Tests |
|
|
|
|
|
|
|
|
Insulation Continuity Test Voltage | kV | 30.5 | 30.5 | 30.5 | 63 | 63 | 30.5 | 63 | |
Insulation construction process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process | Through simultaneous triple extrusion process |
Product detail pictures:

Related Product Guide:
Persisting in "High high quality, Prompt Delivery, Aggressive Price", we've established long-term cooperation with clients from the two overseas and domestically and get new and old clients' superior comments forOEM Famous RF module Quotes –Medium Voltage Copper Cable– Holley, The product will supply to all over the world, such as: Detroit, Philippines, Madrid, Strong infrastructure is the need of any organization. We are backed with a robust infrastructural facility that enables us to manufacture, store, quality check and dispatch our products worldwide. To maintain smooth work flow, we have sectioned our infrastructure into a number of departments. All these departments are functional with latest tools, modernized machines and equipment. Owing to which, we are able to accomplish voluminous production without compromising upon the quality.