Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for OEM Factory for China Medium Voltage Power Cables Single Core Copper Cables, We put sincere and health as the primary responsibility. We have a qualified international trade group which graduated from America. We’re your next business partner.
Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for China PVC Insulated Power Cable, Fire-Resistant Power Cable, Our tenet is “integrity first, quality best”. We have now confidence in providing you with excellent service and ideal items. We sincerely hope we can establish win-win business cooperation with you in the future!
Specifications
DESCRIPTION |
UNIT |
VALUE |
VALUE |
VALUE |
VALUE |
VALUE |
VALUE |
VALUE |
|
1 |
GENERAL |
|
1X70mm2 8.7 / 15 (17.5) kV |
1x120mm2, 8.7 / 15 (17.5) kV |
1×150 mm2, 8.7 / 15 (17.5) kV |
1x70mm2, 18/30 (36) kV |
1X120mm2 FOR 18/30 (36) kV |
1×185 mm2, 8.7 / 15 (17.5) kV |
1X185mm2 FOR 18/30 (36) kV |
|
Standard |
|
NTP IEC 60502-2 |
NTP IEC 60502-2 |
NTP IEC 60502-2 |
NTP IEC 60502-2 |
NTP IEC 60502-2 |
NTP IEC 60502-2 |
NTP IEC 60502-2 |
2 |
DESIGNATION N2XSY |
1 x 70 mm2 |
1 x 120 mm2 |
1 x 150 mm2 |
1 x 70 mm2 |
1 x 120 mm2 |
1 x 185 mm2 |
1 x 185 mm2 |
|
|
Rated Voltage Uo / U (Uo) |
kV |
8.7 / 15 (17.5) |
8.7 / 15 (17.5) |
8.7 / 15 (17.5) |
18/30 (36) |
18/30 (36) |
8.7 / 15 (17.5) |
18/30 (36) |
|
Maximum temperature under normal conditions |
° C |
90 |
90 |
90 |
90 |
90 |
90 |
90 |
|
Maximum short-circuit temperature (5 s. Maximum) |
° C |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
3 |
PHASE CONDUCTOR | ||||||||
|
Standard |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
NTP IEC 60228 |
|
|
Material |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
Uncoated Annealed Copper |
|
|
Purity |
% |
99.9 |
99.9 |
99.9 |
99.9 |
99.9 |
99.9 |
99.9 |
|
Nominal section |
mm2 |
70 |
120 |
150 |
70 |
120 |
185 |
185 |
|
Class |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|
|
Minimum number of wires |
No. |
19 |
37 |
37 |
19 |
37 |
37 |
37 |
|
Density at 20 ° C |
gr / cm3 |
8.89 |
8.89 |
8.89 |
8.89 |
8.89 |
8.89 |
8.89 |
|
Electrical resistivity at 20 ° C |
Wmm2 / m |
0.017241 |
0.017241 |
0.017241 |
0.017241 |
0.017241 |
0.017241 |
0.017241 |
|
Maximum electrical resistance in DC at 20 ° C |
Ohm / km |
0.268 |
0.153 |
0.124 |
0.268 |
0.153 |
0.099 |
0.099 |
|
Insulation | ||||||||
Material |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
XLPE-TR (Tree Retardant Cross-linked Polyethylene) |
||
Colour |
natural |
natural |
natural |
natural |
natural |
natural |
natural |
||
Average nominal thickness |
mm |
4.5 |
4.5 |
4.5 |
8 |
8 |
4.5 |
8 |
|
|
Screen |
|
|
|
|
|
|
|
|
Semiconductor tape or extruded compound semiconductor on the conductor |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
||
About the insulator | |||||||||
Semiconductor tape or extruded composite semiconductor |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
||
|
Copper wire braided mesh or tape with resistance less than 3 ohm/km at 20 ° C |
|
YES |
YES |
YES |
YES |
YES |
YES |
YES |
Sheath | |||||||||
Material |
PVC –ST2 |
PVC – ST2 |
PVC – ST2 |
PVC –ST2 |
PVC – ST2 |
PVC – ST2 |
PVC – ST2 |
||
Colour |
Red |
Red |
Red |
Red |
Red |
Red |
Red |
||
Minimal thickness |
mm |
1.2 |
1.2 |
1.3 |
1.4 |
1.5 |
1.4 |
1.6 |
|
|
Tests |
|
|
|
|
|
|
|
|
Insulation Continuity Test Voltage |
kV |
30.5 |
30.5 |
30.5 |
63 |
63 |
30.5 |
63 |
|
Insulation construction process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Through simultaneous triple extrusion process |
Often customer-oriented, and it’s our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for OEM Factory for China Medium Voltage Power Cables Single Core Copper Cables, We put sincere and health as the primary responsibility. We’re your next business partner.
OEM Factory for China PVC Insulated Power Cable, Fire-Resistant Power Cable, Our tenet is “integrity first, quality best”. We have now confidence in providing you with excellent service and ideal items. We sincerely hope we can establish win-win business cooperation with you in the future!