Featured

  • OEM Famous Prime module Factory –  Pin Type Porcelain Insulator ANSI 56-2 – Holley

    OEM Famous Prime module Factory – Pin Type Porcelain Insulator ANSI 56-2 – Holley

    Specifications No. FEATURES UNIT VALUE 1 Standard ANSI C-29.6 2 Insulating material Porcelain 3 ANSI class 56-2 4 Insulator rated voltage kV 24 5 Dimensions Creepage distance mm. 434 Dry arc distance mm. 210 6 Cantilever strength kN. 13 7 Breakdown voltage kV. 145 8 Low frequency disruptive voltage - Dry kV. 110 - In the rain kV. 70 9 Critical impulse voltage - positive kVp. 175 - negat...
  • OEM Famous Busbar Factory –  Suspension type Polymeric Insulator – Holley

    OEM Famous Busbar Factory – Suspension type Polymeric Insulator – Holley

    Specifications   Products Type   SUSPENSION TYPE POLYMERIC INSULATOR 13.8 kV SUSPENSION TYPE POLYMERIC INSULATOR 22.9 kV   Features Unit Value Value 1 Operating voltage (Phase – Phase)   ≤ 13.8 kV ≥13.8 kV , ≤22.9 kV 2 Designation, model FXB-24kV/70kN FXB-36kV/70kN 3 Standards IEC 61109:2008, ANSI C29.13 IEC 61109:2008, ANSI C29.13 4 Manufacturing Features Core material Fiberglass with Fiberglas Round Rod Bar ECR Fiberglass ...
  • China OEM Prepayment system Company –  Medium Voltage Copper Cable  – Holley

    China OEM Prepayment system Company – Medium Voltage Copper Cable – Holley

    Specifications DESCRIPTION UNIT VALUE VALUE VALUE VALUE VALUE VALUE VALUE 1 GENERAL   1X70mm2 8.7 / 15 (17.5) kV 1x120mm2, 8.7 / 15 (17.5) kV 1×150 mm2, 8.7 / 15 (17.5) kV 1x70mm2, 18/30 (36) kV 1X120mm2 FOR 18/30 (36) kV 1×185 mm2, 8.7 / 15 (17.5) kV 1X185mm2 FOR 18/30 (36) kV   Standard    NTP IEC 60502-2  NTP IEC 60502-2  NTP IEC 60502-2  NTP IEC 60502-2  NTP IEC 60502-2  NTP IEC 60502-2  NTP IEC 60502-2 2 DESIGNAT...
  • OEM Famous Single phase smart prepayment meter Factories –  HYW-12 Series Ring Cage – Holley

    OEM Famous Single phase smart prepayment meter Factories – HYW-12 Series Ring Cage – Holley

    Product Usage HYW-12 series ring cage is a compact and expandable metal enclosed switchgear, which uses FLN-12 SF6 load switch as the main switch and the whole cabinet is air insulated, suitable for distribution automation. HYW-12 has the advantages of simple structure, flexible operation, reliable interlocking, convenient installation, etc. Normal use environment Altitude:1000m Ambient temperature: maximum temperature: +40℃; minimum temperature: -35℃ Ambient humidity: daily average value do...
  • OEM Famous 3-20kV Potential Transformer Companies –  10KV Full Enclosed Combination Transformer – Holley

    OEM Famous 3-20kV Potential Transformer Companies – 10KV Full Enclosed Combination Transformer – Holley

    Overview This type of combined transformer is a fully enclosed indoors (outdoors) product vacuum casted of epoxy resin. It has the good properties contains high insulation grade, anti-pollution ability, anti-ultraviolet and good hydrophobicity. The secondary outlet port is equipped with anti-tamper protective cover with rainproof, dustproof and corrosion resistant. The umbrella-proof skirt design is adopted in appearance, with long creepage distance on the surface. It is mainly used for elect...
  • China OEM Card meter Suppliers –  Single&Three Phase DIN Rail Meter Box – Holley

    China OEM Card meter Suppliers – Single&Three Phase DIN Rail Meter Box – Holley

    Specifications Nominal Voltage 230/400V Rated Isolation voltage 1kV Rated Frequency 50Hz Rated Current 63A Rated Short-circuit current @1s 6kA Enclosure Material ABS+PC Installation location Indoor/Outdoor Protection Class IP54 Seismic Capacity IK08 Fireproof Performance UL94 – V0 Color Gray Varistor Imax 20kA Standard IEC 60529 Dimension PXD1-10:180mm*260.4mm*130.6mm PXD2-40:270mm*139mm*350mm High performance High temperature resistance Advanced anti-rust...
  • OEM Famous All aluminum alloy conductor Manufacturers –  Self-Supporting Aluminum Cable  – Holley

    OEM Famous All aluminum alloy conductor Manufacturers – Self-Supporting Aluminum Cable – Holley

    Specifications DESCRIPTION UNIT VALUE VALUE VALUE VALUE VALUE 1 GENERAL   3×35 + 1×16 + NA25 mm2 3×50 + 1×16 + NA35mm2 3×70 + 1×16 + NA50 mm2  3×25 + 1×16 + NA25 mm2  3X120 + 1X16 + NA70 mm2   Manufacturing standard   NTP 370.254 NTP 370.254 NTP 370.254 NTP 370.254 NTP 370.254 2 DESIGNATION CAAI CAAI CAAI CAAI CAAI   Rated Voltage Uo / U kV 0.6 / 1 0.6 / 1 0.6 / 1 0.6 /...
  • OEM Famous AMR meter Suppliers –  HYW-12 Series Ring Cage – Holley

    OEM Famous AMR meter Suppliers – HYW-12 Series Ring Cage – Holley

    Product Usage HYW-12 series ring cage is a compact and expandable metal enclosed switchgear, which uses FLN-12 SF6 load switch as the main switch and the whole cabinet is air insulated, suitable for distribution automation. HYW-12 has the advantages of simple structure, flexible operation, reliable interlocking, convenient installation, etc. Normal use environment Altitude:1000m Ambient temperature: maximum temperature: +40℃; minimum temperature: -35℃ Ambient humidity: daily average value do...
  • OEM Famous Miniature Circuit Breaker Suppliers –  Silver Electrolytic Copper Expulsion Fuse – Holley

    OEM Famous Miniature Circuit Breaker Suppliers – Silver Electrolytic Copper Expulsion Fuse – Holley

    Specifications Product Type   EXPULSION FUSE CUT OUT, 27 kV, 150kVBIL, 100 A 8/12kA, 470mm CREEPAGE DISTANCE EXPULSION FUSE CUT OUT, 38kV, 170kVBIL, 100A, 5/8 kA, 660mm CREEPAGE DISTANCE EXPULSION FUSE CUTOUT, 27kV, 150kVBIL, 200A, 7.1/10 kA, 432mm CREEPAGE DISTANCE No. Features Unit Value Value Value 1 BASE   Model HV1-27/100-8  HV1-38/100-5 HV1-27/200-7.1 Standard ANSI/IEEE C 37.40/41/42  IEC60282- 2:2008 ANSI C-37.40/41/42 and IEC60282-...
  • OEM Famous 3-phase 4-wire meter Manufacturers –  HYW-12 First And Second Ring Cage – Holley

    OEM Famous 3-phase 4-wire meter Manufacturers – HYW-12 First And Second Ring Cage – Holley

    Product Usage According to the requirements of State Grid Corporation’s “Typical Design of Distribution Primary and Secondary Complete Equipment”, it consists of loop-in and loop-out units, feeder units, busbar equipment (PT) units and centralized DTU units,And integrated with electronic current sensor and line loss collection terminal. The DTU unit realizes functions such as three-temperature, cable measurement, short-circuit/ground fault handling, communication, and secon...
  • OEM Famous Arrester Quotes –  PIN type Polymeric Insulator – Holley

    OEM Famous Arrester Quotes – PIN type Polymeric Insulator – Holley

    Specifications Features Unit VALUE VALUE PIN TYPE POLYMERIC INSULATOR 13.8 kV PIN TYPE POLYMERIC INSULATOR 22.9 kV 1 Operating Voltage(Phase-Phase) ≤ 13.8 kV ≥13.8 kV , ≤22.9 kV 2 Insulator model FPQ-24kV/12kN FPQ-35kV/12kN 3 Standard IEC 61952:2008 IEC 61952:2008 4 Design and construction features Core material (core) Fiberglass with Fiberglas Round Rod Bar ECR Fiberglass with Fiberglas Round Rod Bar ECR Insulated housing an...
  • China OEM 1-phase 2-wire meter Company –  Single&Three Phase  Meter Box – Holley

    China OEM 1-phase 2-wire meter Company – Single&Three Phase Meter Box – Holley

    Specifications Nominal Voltage 230/400V Rated Isolation voltage 1kV Rated Frequency 50Hz Rated Current 63A Rated Short-circuit current @1s 6kA Enclosure Material PC, ABS, Alloy, Simple metal (Optional) Installation location Indoor/Outdoor Protection Class IP54 Seismic Capacity IK08 Fireproof Performance UL94 – V0 Color Gray Varistor Imax 20kA Standard IEC 60529 Dimension HLRM-S1:209.5mm*131mm*400mm PXS1:323mm*131mm*550mm High performance Advanced anti-rust...